Who's Online
There currently are 5670 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Excellent transaction - clean document received - Thanks a lot
;
Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
;
We received the manual in a timely manner and it was exactly what we were expecting.
;
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
;
Very good scanning quality. All schematics are very legible. Worth every cent !
XV-IS22DVD
FL
39
Description of Error
Causes if with a DVD
SGC could not converge during detects the peak
Causes if with a CD
Operation of the Unit
Open Stop
SGC converge timeout 41 Spindle timeout
The unit did not enter Stop mode within 10 seconds of issuance of a Stop command. The spindle could not converge into within ± 12% of the target FG rotation speed within 10 seconds after spindle kick. The first time after startup (the first time after disc distinction), it doesn't become the number of the target rotation within five seconds. The first time after startup, detects the abnormal rotation number of high-speed continuously 3 loops. DVD: 5 to 9 mS , CD: 40 to 60 mS After the second times after startup, it doesn't become the number of the target rotation within five seconds. Detects the abnormal high-speed or low-speed rotations. DVD: 5 to 9 mS , CD: 40 to 60 mS
48
Spindle FG transition timeout
Stops. (FG timeout)
Spindle PLL 49 transition timeout
Stops. ("73" is displayed during starting process.) Stops. ("73" is displayed during starting process.) Stop
4A Spindle lock timeout Spindle could not lock more than 1.5 seconds before start the AFB. 51 Auto sequence timeout of peak ABUSY did not return within 1 second after the DDTCT (peak detection) command was sent. ABUSY did not return within 30 mS after the FJMPD (Focus jump 1 to 0) command was sent. ABUSY did not return within 30 mS after the FJMPU (Focus jump 0 to 1) command was sent.
Auto sequence 52 timeout of focus jump down 53 54 Auto sequence timeout of focus
Stop
Stop Stop Stop
Auto sequence ABUSY did not return within 50 mS after the GSUMON timeout of play AGC (play-AGC-measuring) command was sent. ABUSY did not return within 2 seconds after the DJSRT (disc-sensing) command was sent. ABUSY did not return within 1 second after the TBLOFS (Internal ATB after the completion of external ATB) command was sent. ABUSY did not return within 500 mS after the TSON (tracking servo ON) command was sent. ABUSY did not return within 200 mS after the TBL (external ATB) command was sent. ABUSY did not return within 2 seconds after the FGN (focus gain adjustment) command was sent. ABUSY did not return within 2 seconds after TGN (tracking gain adjustment) command was sent. ABUSY did not return within 1 second after the CMDAVE (offset adjustment) command was sent. ABUSY did not return within 200 mS after the ADJMIR (modulation factor measurement) command was sent. ABUSY did not return within 2 seconds after the AFB (auto focus bias) command was sent. A command could not be sent because ABUSY was low. ABUSY did not return within 200 mS after TLV command was sent. Pause mode could not be restored within three retries after it had been released. An ID could not be read for 1 second or more. No frame could be read for 3 seconds or more. An ID could not be read within 1 second after the AFB adjustment had been finished.
Auto sequence 55 timeout of disc-typesensing Auto sequence 56 timeout of ATB2 Auto sequence 57 timeout of tracking servo ON Auto sequence 58 timeout of ATB1 Auto sequence 59 timeout of focus gain adjustment Auto sequence 5A timeout of tracking gain adjustment Auto sequence 5B timeout of offset adjustment Auto sequence 5C timeout of modulation factor measurement Auto sequence 5D timeout of auto focus bias Auto sequence 5F already busy 62 Pause retry error 71 ID can not read during tracing
Stop
Stop Stop Stop
Stop
Stop
Stop
Stop
Stop Continues operation Stop Stop
72 Subcode check failure during playback 73 ID can not read at the startup
Opens (ID readout failure)
74
|
|
|
> |
|