Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 347 guests and 
3 members online.
Categories
Information
Featured Product
Home >> PIONEER >> XCIS21MD I Service Manual
 
 0 item(s) in your cart 

PIONEER XCIS21MD I
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of PIONEER XCIS21MD I Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 SC-3330 SANSUI Service Manual by Marc LO BONO;
Acurate informations inside the SM and I could repair my old Sansui SC-3330 without any problems. Thanks.
 7045 NAD Service Manual by Marc LO BONO;
I used it to repair a NAD 7030, but unfortunately, the 7045 is different ! But documentation was useful.
 STR-4800 SONY Service Manual by Marc LO BONO;
Content A4 and A3 format pages. Exactly what I needed to restore my old receiver.
 STR-5800 SONY Service Manual by Marc LO BONO;
Content A4 and A3 format pages. Exactly what I needed to restore my old receiver.
 DCX 6000K SANYO Service Manual by Marc LO BONO;
Thanks you very much for this "hard to find" service manual. Will help a lot in repairing this receiver.

Text excerpt from page 59 (click to view)
XC-IS21MD
6.1.3 MD Mechanism Assy Adjustment and Check
1 Temperature Check (Please perform this check soon after the power has been switched on.)
Note: When IC101 (RF-AMP) or IC104 (mechanical controller) has been exchanged or when a correction changing VD+3 has been made, be sure to correctly perform all steps up to step 6.
Step No. 1 Operation Keys and Operation Method Short circuit MECH TEST MODE during the power ON. (Fig.6-1) Press the REC key. When is 80 or more at this time, the adjustment is OK (step 4 and following can be omitted). is 80 (not passed) Measure the ambient temperature T (°C) andcheck hat the measuring value ( ) is within the standard in regard to the microcomputer set value ( ). Note: When the indication of the measuring value ( ) is not stable, and the ambient temperature T (°C) is 25 °C or less, set to the lower value. When the ambient temperature is over 25 °C, set to the higher value. TEMP 80 FL Display EJECT Test mode Status Remarks

2 3 When 4

TEMP

The microcomputer starts measuring. End 80 is the default value (unadjusted).
TEMP

: Measuring value : Set value

µ-com Measuring value Room Temperature [ T (°C) ] 11.6 to 16.9 17.0 to 22.3 22.4 to 27.6 27.7 to 33.0 33.1 to 38.4 ( hex= – +1 to +3 0 to +2 –1 to +1 0 to –2 –1 to –3 )

µ-com Set value

79 When the 7A microcomputer 7B value is 7C 7D

–

+

5 6

Change with the F. SKIP key (UP) and the R.SKIP key (DOWN). Power OFF

TEMP 7B 7B EEPROMW Writing to EEPROM is made and return is made automatically from test mode to normal mode.

2 Laser Power Check CAUTION
• Never look directly at the objective lens. Rec power (rpw) is than ten times greater than Playback power (ppw) is released. • Never turn the pickup volume and be careful of touch it. Laser power of pickup has been adjusted in the factory shipping.
Step No. 1 Operation Keys and Operation Method Short circuit MECH TEST MODE during the power ON. (Fig6-1) Press the ENTER key Measure the laser power with an optical power meter. At this time, check that the measuring value (PLAY power) meets the standard value of the table on the right. Note: When the standard value on the right is applied, the numerical value immediately after entry into test mode 2 shall be taken as the standard. FL Display EJECT Test mode Status Remarks Laser Wavelength: 780 nm

2 3 4

ppw ppw ppw

PLAY power output status

µ-com Measuring value
hex = ( – ) +02 to +04 –01 to +01 –02 to –04

TEMP

May be omitted.

µ-com Set value
Standard Value (mW) 0.69±0.12 0.67±0.1 0.63±0.1

5 6

Press the ENTER key. At this time, check that the measuring value (REC power) meets the standard value of the table on the right.

rpw rpw

REC power output status ( hex = – ) +02 to +04 –01 to +01 –02 to –04 Standard Value (mW) 6.18±0.93 5.79±0.87 5.47±0.82

7

Press the EJECT key.

The LD goes out.

59

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG-7500 PANASONIC
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

HC-P4752W SAMSUNG
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…