Who's Online
There currently are 5770 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Great manual, great price. Has a few of the basic operating instructions that most service manuals leave out. Complete instructions for disassembling board by board, safety precautions, schematics, complete parts list.
;
I am very pleased with the service manual for my RT-909. This was an easy purchase and great procuct, and much cheaper than other venues i had looked at. This web site is now listed in my favorites list. KEEP UP THE GOOD WORK. THANKS. J. BROWN
;
A very well written and easy to understand manual.
;
There was no problem at all.After paying i had to wait only a few hours,than i could
download the manual in best pdf-quality.
Thank You !
;
I found this service manual to be complete in every detail except for troubleshooting charts. It would be helpful if it had a set of troubleshooting charts; however it is a very good manual otherwise and for the price it is very well worth it.
1
2
3
4
7.1.5 Circuit Description
A
1 Protection circuit when the edge of speaker is oveload
R325 330 R317 0.22
3 FAN detection circuit
CN305 +5.6V R405 R407 10k 1k C402 0.01
POWER Assy A
FL
FAN+ FANFAN.STOP
1 2 3
D401 R408 100k
B
R327 1.8k D301 Q305
To µ-COM FAN DCT
FRONT Assy
SP edge GND FL +5V R4243 10k To µ-COM ODCT
D410 UDZS5.1B
D303 DAP202K
When FAN is not connected between FAN+ and FAN-, or an alien substance is clogged up in the FAN at the FAN LOCK status, FAN STOP becomes the same electric potential as the FAN- (Low). � µ-COM detects it, and turn the power OFF.
B
A speaker (6�) is connected between FL and GNDFL normally. Q305 (306) (345) (346) (383) does not work because the voltage of A point is higher than B point. If a resistance value between FL and GNDFL becomes less than 1.2�, Q305 (306) (345) (346) (383) turns ON. And ODCT becomes with negative component of output level. � µ-COM detects it, and turn the power OFF.
C
2 DC detection circuit of SP terminal
R331 22k FL R332 22k FR R371 22k RL R372 22k RR DDCT R392 22k C R396 10k C391 220/10 Q384 Q385 +5V
POWER Assy
R4244 47k
D
FRONT Assy
� Q384 and Q385 are turning OFF together normally. (1) When the DC voltage of the plus (+) side was generated on the SP edge When the DC voltage of the plus (+) side was generated in L ch or R ch, Q384 turns ON and DDCT becomes Low level if VB of Q384 becomes higher than operating point. � µ-COM detects it, and turn the power OFF. (2) When the DC voltage of the minus (-) side was generated on the SP edge Q385 turns ON with + side in reverse, and DDCT works.
E
F
58
1 2
VSX-C100-S