Who's Online
There currently are 5879 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This service manual helped me to repair my PIONEER. Iam very satisfied, that I found it here.
Even the price of manual was not so high that person would not be able to spend a few money.
But that is very worth spent money. Thanks
;
Excellent quality service manual. Quick processing, fair prices. Love to do business again. Thank you!!!
;
Excellent service manual, the only known point of note is the alignment of improvability scanned pages within the pdf page. The resolution is good.
;
I was very glad recieving the service manal from You. Additionaly very fast. Extremaly nice servicing. Thanks very mach! Now my GX-220 working better, than it was made. Alexander from Moscow, Russia/
;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
5
6
7
8
A Step 2-3: Input selection Step 2-5: SDA/SCL
CN1001 (Pin 5) Is the voltage "L" when selecting IN1? And is the voltage "H"(5V) when selecting IN2? Yes CN1001 (Pin 4) SELB SELA IC102 (Pin 7) No Diagnose the MAIN Assy. Does a signal output in constant period (0 to 5 V) ? Yes IC102 (Pin 9) SDA (HDMI OUT)
A
No Check the JA301 and IC102. If JA301 or IC102 is failure, replace JA301 or IC102.
SCL (HDMI OUT)
B
Is the voltage "H"(5V) when selecting IN1? And is the voltage "L" when selecting IN2? Yes
No Diagnose the MAIN Assy.
Does a clock output in constant period (0 to 5 V) ? Yes IC101 (Pin 39) Is there a same signal as IC102-pin 7 (0 to 3.3V) ? Yes IC101 (Pin 38)
No Check the JA301 and IC102. If JA301 or IC102 is failure, replace JA301 or IC102.
SDA_SINK
Step 2-4: Hot Plug Detect
CN1001 (Pin 7) HPD_IN
No Check the IC102 and IC101. If IC102 or IC101 is failure, replace IC102 or IC101.
C
Is the voltage "H" (5 V)? Yes CN1001 (Pin 6)
No Check the JA301. If JA301 is failure, replace JA301.
SCL_SINK
HPD_SINK
Is the voltage "H" (5 V)?
No Diagnose the MAIN Assy.
Is there a same No Check the IC102 and IC101. signal as IC102-pin 9 If IC102 or IC101 is failure, (0 to 3.3V) replace IC102 or IC101. ? Yes * When connected the source equipment to IN1;
D
IC101 (Pin 63) Yes * When connected the source equipment to IN1; JA101 (Pin 19) Is the voltage 5 V when selecting IN1? HPD0 Check the IC101 and JA101. If IC101 or JA101 is failure, replace IC101 or JA101.
SDA (HDMI IN1)
No
Is there a same No Check the IC101 and JA101. signal as IC102-pin 7 If IC101 or JA101 is failure, when selecting replace IC101 or JA101. IN1? (0 to 5 V) Yes IC101 (Pin 64) SCL (HDMI IN1)
Yes * When connected the source equipment to IN2; JA102 (Pin 19) Is the voltage 5 V when selecting IN2? Yes HPD1
No
Check the IC101 and JA102. If IC101 or JA102 is failure, replace IC101 or JA102.
Is there a same No Check the IC101 and JA101. signal as IC102-pin 9 If IC101 or JA101 is failure, when selecting replace IC101 or JA101. IN1? (0 to 5 V) Yes
E
B
F