Who's Online
There currently are 5423 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Exactly what was needed to assess the product - excellent value and great service
;
Nice to have the service manual for the Sony DCR-TRV345E now. The document is of excellent quality.
;
MACKIE HR824 26 pages English-only Service Manual contains:
1) HR824 technical overview with the description of front and rear panel switches.
2) HR824 specs
3) Block Diagram
4) Wiring Diagram
5) Packaging management
6) Spare part & final assembly list (for PCB rev A and B) + exploded view
7) Test Procedures (where, how to measure voltage...) including Test Point diagram on the PCB.
8) IC and Transistor charts.
Excellent guide: very clear, good scan quality enabling us to print readable diagram :-)
Note:
Mackie HR824 make extensive use of surface mount devices (SMD). Service on the HR824 must
only be undertaken by experienced service technicians with the right tools, experience and patience to perform surface mount rework when needed.
;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
5
6
7
8
A Step 2-3: Input selection Step 2-5: SDA/SCL
CN1001 (Pin 5) Is the voltage "L" when selecting IN1? And is the voltage "H"(5V) when selecting IN2? Yes CN1001 (Pin 4) SELB SELA IC102 (Pin 7) No Diagnose the MAIN Assy. Does a signal output in constant period (0 to 5 V) ? Yes IC102 (Pin 9) SDA (HDMI OUT)
A
No Check the JA301 and IC102. If JA301 or IC102 is failure, replace JA301 or IC102.
SCL (HDMI OUT)
B
Is the voltage "H"(5V) when selecting IN1? And is the voltage "L" when selecting IN2? Yes
No Diagnose the MAIN Assy.
Does a clock output in constant period (0 to 5 V) ? Yes IC101 (Pin 39) Is there a same signal as IC102-pin 7 (0 to 3.3V) ? Yes IC101 (Pin 38)
No Check the JA301 and IC102. If JA301 or IC102 is failure, replace JA301 or IC102.
SDA_SINK
Step 2-4: Hot Plug Detect
CN1001 (Pin 7) HPD_IN
No Check the IC102 and IC101. If IC102 or IC101 is failure, replace IC102 or IC101.
C
Is the voltage "H" (5 V)? Yes CN1001 (Pin 6)
No Check the JA301. If JA301 is failure, replace JA301.
SCL_SINK
HPD_SINK
Is the voltage "H" (5 V)?
No Diagnose the MAIN Assy.
Is there a same No Check the IC102 and IC101. signal as IC102-pin 9 If IC102 or IC101 is failure, (0 to 3.3V) replace IC102 or IC101. ? Yes * When connected the source equipment to IN1;
D
IC101 (Pin 63) Yes * When connected the source equipment to IN1; JA101 (Pin 19) Is the voltage 5 V when selecting IN1? HPD0 Check the IC101 and JA101. If IC101 or JA101 is failure, replace IC101 or JA101.
SDA (HDMI IN1)
No
Is there a same No Check the IC101 and JA101. signal as IC102-pin 7 If IC101 or JA101 is failure, when selecting replace IC101 or JA101. IN1? (0 to 5 V) Yes IC101 (Pin 64) SCL (HDMI IN1)
Yes * When connected the source equipment to IN2; JA102 (Pin 19) Is the voltage 5 V when selecting IN2? Yes HPD1
No
Check the IC101 and JA102. If IC101 or JA102 is failure, replace IC101 or JA102.
Is there a same No Check the IC101 and JA101. signal as IC102-pin 9 If IC101 or JA101 is failure, when selecting replace IC101 or JA101. IN1? (0 to 5 V) Yes
E
B
F
VSX-918V-K
5 6 7 8
43
|
|
|
> |
|