Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
Perfect source of information for replacing the HDD and performing general diagnostics.
Text excerpt from page 13 (click to view)
5
6
7
8
Main flowchart (2)...Checking VOL YNOFSA D
[From the Main flowchart (1)]
Display RST MASK 21 (Red 1023+). / [MKR S21]
A
Set VOL YNOFSA D to the tentative setting value 103. / [VYF 103]
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No Display RST MASK 22 (Green 1023+). / [MKR S22]
Yes
To the Recovery flowchart (2-1)
B
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No
Yes
To the Recovery flowchart (2-2)
C
Display RST MASK 15 (Magenta 120). / [MKR S15]
Set VOL YNOFSA D to the tentative setting value 151. / [VYF 151]
Is there erroneous discharge (abnormal lit cell)? (Check on the PANEL 1-ADJ menu.) No
Yes
To the Recovery flowchart (2-3)
Return the VOL YNOFSA D to the tentative setting value 128. / [VYF 128]
D
Determine the tentative setting value for VOL YNOFSA D as the final value.
From the Recovery flowchart (2-2) and (2-3)
[Adjustment completed]
E
Note: Make sure that the following values become the final setting values. VOL SUS *1 VOL XPOSF2 *1 VOL OFFSET VOL YNOFS1 D *1 VOL RST P *1 VOL YNOFS3 D *1 VOL XPOFS1 *1 VOL YNOFS4 D *1 VOL YNOFS4 A *1: The tentative setting value becomes the final value.
F