Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 6042 guests and 
1 member online.
Categories
Information
Featured Product
Home >> PIONEER >> PDP-50MXE1/T/E1 Service Manual
 
 0 item(s) in your cart 

PIONEER PDP-50MXE1/T/E1
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of PIONEER PDP-50MXE1/T/E1 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 KVX2991A SONY Service Manual by Matteo Vannini;
As Always you can find here manuals even of difficult TV scheme which are scan in almost perfect way.clear and fast!!!!! Great work thanks!
 NEMOS 32 LOEWE Service Manual by Matteo Vannini;
Incredibly clear!!!! Well done, complete and wonderful. It could not better than this!!!!
 PA-770 AKAI Service Manual by Franz Steinberger;
Thank You for fast delivery for the sheme. Everything allright. Thanks & best regards Franz
 SE9000 SAMSUNG Service Manual by Matteo Vannini;
again you did a very good job. It was fast too. Photocopy are really readable and clear
 1081 COMMODORE Service Manual by Marco Antonio Romero Garcia;
Probably it never existed a 1081 official service manual from Commodore, it's look more like a NAPCEC service manual & diagrams compilation of the 1084 series and his variants, like the nap6523, 8cm505, 1084S, 1084P and obviously the 1081. It's more complete than other scans and the quality of the scans also are far superior. It has two circuit diagrams variants of the 1081, mono and stereo versions. It doesn't include a diagram for the Philips CM8500 or CM8501, they look like the 1081 but they are slightly different.

Text excerpt from page 5 (click to view)
5

6

7

8

Charged Section
The places where the commercial AC power is used without passing through the power supply transformer. If the places are touched, there is a risk of electric shock. In addition, the measuring equipment can be damaged if it is connected to the GND of the charged section and the GND of the non-charged section while connecting the set directly to the commercial AC power supply. Therefore, be sure to connect the set via an insulated transformer and supply the current.

High Voltage Generating Point
The places where voltage is 100 V or more besides the live parts are described above. You must not touch them, since there is risk of electric shock. The VSUS voltage remains for several minutes after the power to the unit is turned off. These places must not be touched until about 10 minutes after the power is turned off, or it is confirmed with a tester that there is no residual VSUS voltage. 1. POWER SUPPLY Unit.....................................................(223V) 2. 50 X DRIVE Assy ...........................................(�230V to 223V) 3. 50 Y DRIVE Assy ...........................................................(353V) 4. 50 SCAN A Assy ............................................................ (353V) 5. 50 SCAN B Assy ............................................................ (353V) 6. X CONNECTOR A Assy ................................(�230V to 223V) 7. X CONNECTOR B Assy ............................... (�230V to 223V) Discharge the VSUS voltage, as shown below: [Method for discharging the VSUS voltage] 1. Set DRF_SW on the DIGITAL VIDEO Assy to ON (Drive OFF status). �1, �2 2. Leave the switch at that position for about 20-30 seconds. 3. If the power is on, turn it off. Then return DRF_SW to the OFF position. �3 Notes �1: You can also set the unit to "Drive OFF status" by sending the "DRF" RS232C command from the PC. �2: DRF_SW can be switched whether the power is on or off. �3: Power-down will occur if DRF_SW is set to OFF while the power is on. (See "7.1.5 POWER ON/OFF FUNCTION FOR THE LARGE-SIGNAL SYSTEM".)
POWER SUPPLY Unit 50 X DRIVE Assy X CONNECTOR B Assy
A

1. Power Cord 2. AC Inlet with Filter 3. Power Switch (S1) 4. Fuse (In the POWER SUPPLY Unit) 5. STB Transformer and Converter Transformer (In the POWER SUPPLY Unit) 6. Other primary side of the POWER SUPPLY Unit

B

C

50 inch model
: Part is Charged Section. : Part is the High Voltage Generating Points other than the Charged Section. 50 SCAN B Assy 50 Y DRIVE Assy

D

E

50 SCAN A Assy

Power Switch (S1)

AC Inlet with Filter

X CONNECTOR A Assy Power Cord
F

Fig.1 Charged Section and High Voltage Generating Point (Rear view)

PDP-504CMX/1
5 6 7 8

5

You might also want to buy

$4.99

PDP-50MXE1/T/E1 PIONEER
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>