Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
- Very good scan quality, PERFECT!
- Sehr gute scan Qualitaet, empfehlenswert!
Wolfgang Sundhaus
;
Good site, works ok and you get what you order, no problems experienced, got my manual within a day. A++++
;
Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
1
2
3
4
A
Recovery flowchart (1-2)
[From the Recovery flowchart (1-1)]
Display RST MASK 09 (red 2). / [MKS S59] Note: Disregard the discharge that may appear during voltage-change setting.
Set VOL OFFSET to the setting value 240. / [VOF 240] Gradually decrease the VOL OFFSET value until disappear the discharge (dead cell).
B
� This setting becomes VOL OFFSET_max1.
VOL OFFSET_max1
Note: Make a note of this VOL OFFSET_max1 value.
VOL OFFSET_max1
107?
No
Replacement of abnormal circuits or re-replacement of the panel required
Yes Display RST MASK 10 (green 2). / [MKS S60]
Set VOL OFFSET to the setting value 240. / [VOF 240]
C
� This setting becomes Gradually decrease the VOL OFFSET value until disappear the discharge (dead cell). VOL OFFSET_max2.
VOL OFFSET_max2
Note: Make a note of this VOL OFFSET_max2 value.
VOL OFFSET_max2
107?
No
Replacement of abnormal circuits or re-replacement of the panel required VOL OFFSET_max
Yes Choose the lower value between VOL_OFFSET_max1 and VOL_OFFSET_max2, and set it as VOL_OFFSET_max.
D
[To the Recovery flowchart (1-3)]
Recovery flowchart (1-3)
[From the Recovery flowchart (1-2)]
Is the VOL OFFSET_max value minus the VOL OFFSET_min value greater than 96? Yes
E
No
Replacement of abnormal circuits or re-replacement of the panel required
Are the VOL OFFSET_max value 165 or greater and the VOL OFFSET_min value 069 or less? Yes Set VOL OFFSET to the setting value 117. / [VOF 117]
No
VOL OFFSET_max
165?
No
Yes Set VOL OFFSET to the setting value VOL OFFSET_max minus 48. Set VOL OFFSET to the setting value VOL OFFSET_min plus 48.
F
Determine the current VOL OFFSET setting value as the final value.
[To the main flowchart (1)]
134
1 2
PDP-5080XA
3 4
|
|
|
> |
|