Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Ottima qualità grafica e completo nelle notizie. Costo abbastanza contenuto.
;
Great and quick support. The maual was exactly what I was looking for and my problem
solved. Many thanks.
;
Very good service Within one day i received a pdf of the users manual and electric circuits so I was able to measure the different voltages in the printed circuit and find out the fault Payment was also reliable and easy.Without the manual i could not have repaired.So thanks to "Search for a manual"
;
you are doing great job guys.....my father ask me to find out the schematics of Sony KV25R1D to sort out the problem ..(he was electrical technician, and excperianced with TV and simillar stuff). finally he found the cause and change all necessary parts....now he has got working old dog..and is very happy!!... thank you all.. NB..he also saved the repair cost.
;
Perfect. Received my manual within 24 hours. Clear scan of the manual I needed. No problem.
MJ-L11
7 Defocus Adjustment
It is possible from steps 3 of this item in the state of step 5 of 6 .
Step No.
1 2 3
Operation Keys and Operation Method
In the Power ON state, selecting MD function,shortcircuit the "MECHA and GNG pin". Insert the test disc GGF1328 (MMD-212). Press the SYSTEM MENU(or MENU) key.(until "deFO AJST" is displayed.) Press the 6(or MD)key. of Defocus Value j
Display
EJECT LOADING GRT AJST deFO AJST PEG : FESpp : of000j0150 Test mode
Status
Remarks
4
Defocus mode is entered, and after automatic execution of normal adjustment.
5 6
Check the jitter value and end the adjustment when the intermediate jitter value is 29 nsec or less. Press the ¶ (REC)of main unit key. of+04 j0130 The C1 error with application of a focus offset of about 0.4µm on the + side is displayed. The jitter value (J+) at this time is recorded. The C1 error with application of a focus offset of about 0.4µm on the � side is displayed. The jitter value (J�) at this time is recorded.
7
Press the ¶ (REC)of main unit key.
of-04 j0120
8
When J+ is larger than J-, press the ¶ (REC) of the main unit key when the focus offset is applied up to +0.4µm. (Do nothig when J- is larger than J+.)
of+04 j0130
9
Change the value with 1 and ¡ keys until the value becomes the same. Press the 6(or MD)key.
of+04 j0132 of+03 j0125 of+02 j0120 COMPLETE
10
When the smaller offset of the jitter value has been corrected mistakenly, press the ENTER(or SET) key and return to step 4. The mean value of the changed set value and the offset of the other setting limit is written into the EEPROM as the compensation offset. Release from the test mode.
11
Turn off the power of the DVD tuner(or CD tuner).
Good Bye
Connection Diagram
Jitter Meter
LEVEL JITTER
MD CORE MAIN UNIT
SIDE A
EFM MON
GND
REFO
36
|
|
|
> |
|