Who's Online
There currently are 6041 guests and 2 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It is wonderful done!!! a great job in scanning the manual. Superior quality in all the electric scheme. Very understandable and net!!! Thank you!
;
muy buen manual por lo completo de este algunos esquemas estan muy divididos lo que hace algo dificil el seguimiento.
;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
1
2
3
4
A
[2] POWER SUPPLY UNIT
Flowchart of Failure Analysis for The POWER SUPPLY Unit
Failure analysis for the POWER SUPPLY Unit => PP1 STB 3.4 V power is not output.
Is the cable connected firmly to the P7 connector? Yes
B
No
Properly connect the cable between the P7 and M2 connectors.
Is the cable to the P7 connector broken? No Is the fuse (F001) blown? No Is one of the limiting resistor (FR002) blown? No The POWER SUPPLY Unit is normal.
Yes Replace the defective cable (J109).
Check the voltage at the MAIN Assy and POWER SUPPLY Unit.
Yes Replace the POWER SUPPLY Unit.
Yes Replace the POWER SUPPLY Unit.
Check the resistance between D025 cathode and C101 (+), using a tester.
C
Failure analysis for the POWER SUPPLY Unit => PP2
The power is not on, even though the RELAY port is active.
No Is the relay (RY002) on? Yes No Is the PFC voltage normal? Yes
D
Replace the POWER SUPPLY Unit.
� Check the relay operation at the RY002. (Voltage: 3.4 V) � Check the relay sound (click).
Replace the POWER SUPPLY Unit.
� Check the voltage between the C017 (-) and C017 (+). � The voltage must be around 400 V. (340V or less are defective.) Caution: High voltage!
The POWER SUPPLY Unit is normal.
Failure analysis for the POWER SUPPLY Unit => PP3
The cells of the panel do not light normally.
Is the VADR voltage within the specified values? Yes
E
No
Replace the POWER SUPPLY Unit.
The specified voltage values are between 72 and 78 V.
Is there a fluctuation in the VADR voltage? No Is the VSUS voltage within the specified range? Yes Is there a fluctuation in the VSUS voltage? No The POWER SUPPLY Unit is normal.
Yes
Replace the POWER SUPPLY Unit.
The ripple must be within 5 V.
No
Replace the POWER SUPPLY Unit.
The specified voltage values are between 200 and 210 V (VSU: 125/35°C).
Yes Replace the POWER SUPPLY Unit.
The ripple must be within 10 V.
F
46
1 2
KRP-500P
3 4
|
|
|
> |
|