Who's Online
There currently are 5903 guests and 3 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I found this service manual to be complete in every detail except for troubleshooting charts. It would be helpful if it had a set of troubleshooting charts; however it is a very good manual otherwise and for the price it is very well worth it.
;
Complete manual included schematics layouts and alignment procedure, clear to read and magnify, extremely pleased with manual and owner manual . com's service
;
perfect, i am very satisfait for the réception of the sansui r-5l service manual, thank you very much
;
Thank you, this is a rare document. Few others have it, but they charge way more for a download.
Great deal (even if you have to wait a few hours to get it).
;
The purchased manual is an high quality scan of the original Philips paper-based Service Manual. I am very satisfied!
1
2
3
4
- How to remove the Control Unit
1. Give jumper-solder treatment to the Flexible Wire of the Pickup unit, then remove the wire from the Connector.
A
Jumper-Solder Control Unit
2. Remove all 4 points of solder-treatment on the Lead Wire. Also, unscrew the screw(1 piece). 3. Then, Remove the Control unit. (Caution) Be careful not to damage SW when you reassemble the Control Unit into the device.
Solder
- How to remove the Loading Arm Assy
1. Unlock the spring (1 piece) and remove the E ring (1 piece) of the Fulcrum Shaft. 2. Shift the arm to the left side direction and unlock pins (2 pieces).
B
Loading Arm Assy
- How to remove the Pickup Unit
C
1. Unscrew 2 pieces of screws, then remove the Pulley Cover. 2. Remove the Feed Screw unit from the pawl of the Feed Screw Guide (The pawl is located inside the guide). 3. Remove the belt from the Pulley, then remove the Pickup unit. (Caution) Pulley Cover Make sure not to stain the belt with grease when you fix the belt.
Pickup Unit Belt
Feed Screw Guide
D
70
1 2
FH-P6100/XN/ES
3 4
|
|
|
> |
|