This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
;
Great service. Fast response. High quality scan. Good price.
Thank you very much!!!
Oleg S.
5
6
7
8
7.1.3 TROUBLE SHOOTING � For RLTXJ only
When set Voltage selector to 120V in the RLTXJ model and had supplied voltage doubler (240V) wrong, and power did not enter normal.
Start
A
Does a primary side fuse (FU1: ACIN assy) blow out? No
Yes
Replace the fuse.
B
Remove the two connectors (CN104 and CN105) from the POWER Assy.
Turn the power ON
Yes
Are the following voltages normal? No
� CN104 - pin 5: +15V, pin 6: -15V � CN105 - pin 5: +15V, pin 6: -15V
C
Are the protector ICs (IC119. IC120, IC112, IC113, IC122-IC125) on the POWER Assy broken? No
Yes
Replace the ICs of the same rating.
Replace the diodes D117-D120 and IC101 on the POWER Assy.
D
No
Are the following voltages normal? Yes
� CN104 - pin 5: +15V, pin 6: -15V � CN105 - pin 5: +15V, pin 6: -15V
Connect the two connectors (CN104 and CN105) on the POWER Assy from the BUS1 and BUS2 Assys.
E
Turn the power ON
End
F
DJM-1000
5 6 7 8
129
|