Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
1
2
3
4
1.3.8 Coefficient display of adjustment results
For some of the adjustments (FE and RF offset, FZD cancel, F and T gains, and RFAGC), the adjustment results can be displayed and confirmed in the test mode. The coefficient display in each auto adjustment is as follows: 1) FE and RF offset Reference value = 32 (coefficient of 32 indicates that no adjustment is required) The value is displayed in the unit of approximately 32 mV. Ex. When the FE offset coefficient is 35, 35 - 32 = 3 x 32 mV = 96 mV The correction is about +96 mV, which means the FE offset before adjustment is - 96 mV. 2) F and T gain adjustment Reference value for focus and tracking = 20
B
A
The displayed coefficient / the reference value indicates the adjusted gain. Ex. When the AGC coefficient is 40, adjustment of 40 / 20 = 2 times (+ 6 dB) has been performed. (It means that the original loop gain was half the target, and the whole gain was doubled to obtain the target value.) 3) RF level adjustment (RFAGC) Reference value = 8 The coefficient of 9 to 15 indicates to increase the RF level (for more gains). The coefficient of 7 to 10 indicates to decrease the RF level
C
(for less gains). When the coefficient changes by 1, the gain changes by 0.7 to 1 dB. When the coefficient is 15, the gain is the maximum at TYP + 7.9 dB. When the coefficient is 0, the gain is the minimum at TYP - 4.6 dB.
D
E
F
16
CX-3195