Excellent quality on these manuals. Same as having the original printed manual and incredibly useful when doing a custom install like me. Keep it up on the good work.
5 stars on this manual since it is the complete version, not the half manual you find free for download all over the web. Good job.
Text excerpt from page 49 (click to view)
5
6
7
8
6.4 SYSTEM MICROCOMPUTER TEST PROGRAM
A
- PCL output
In the normal operation mode (with the detachable panel installed, the ACC switched ON, the standby mode cancelled), shift the TESTIN (Pin 5) terminal to H. The clock signal is output from the PCL terminal (Pin 62). The frequency of the clock signal is 786.432kHz that is one 4th of the fundamental frequency. The clock signal should be 786.432kHz ± 32Hz. If the clock signal is out of the range, the X'tal (X601) should be replaced with new one.