Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
CT-L5
6.2.1 Playback Section
(1) Tape Speed Confirmation
No. 1 Mode PLAY Input Signal/Test Tape NCT-111 (3 kHz) Adjustment Points VR2701 (Main Unit) (Refer to Fig. 6�4) Measurement Points TP R (W183) ( MAIN UNIT) Adjustment Value Remarks FWD adjustment REV Confirmation ( 3000 Hz +60 Hz ) �60
3000 Hz
+10 �10
Hz
(2) Head Azimuth Adjustment
¶ This unit is equipped with auto tape selector. ¶ Do not switch between forward and reverse operation with the screwdriver inserted.
No. Mode Input Signal/Test Tape Adjustment Points Head azimuth adjustment Screw (Fig. 6�4) Measurement Points TP L (W185) TP R (W183) ( MAIN UNIT) Adjustment Value Max. Playback signal level Remarks After adjustment, apply silicon bond to the head azimuth adjustment screw.
1
PLAY
STD-331E test tape (Playback: 10 kHz, �20 dB)
(3) Playback Level Adjustment
¶ Since this adjustment determines playback DolbyNR level, Perform it carefully.
No. Mode Input Signal/Test Tape Adjustment Points L ch R ch Measurement Points TP L (W185) TP R (W183) ( MAIN UNIT) Adjustment Value Remarks
1
PLAY
STD-331E test tape (Playback: 315 Hz, 0 dB)
VR2301 VR2302
�3.7 dBV
6.2.2 Recording Section
(1) Recording Bias Adjustment
¶ After the adjustment, caution should be exercised so as not to become under bias by checking the distortion rate.
No. Mode Input Signal/Test Tape Adjustment Points Measurement Points Adjustment Value Remarks
1
REC/ PAUSE REC = PLAY
Input a 315Hz signal to the AUX � terminal of XC-L5. Load the STD�632 test tape and record/playback the 315Hz and 10kHz signals. (see the Note below)
Input signal level L ch R ch
�23.7 dBV
TP L (W185) TP R (W183) ( MAIN UNIT) Repeat adjustment until playback level of the 10kHz signal is within 0.5dBV ±0.5dB from that of the 315Hz signal.
VR2801 VR2802
2
Note: Set the 10kHz input signal level to the same value as the 315Hz input signal level of step 1.
(2) Recording Level Adjustment
No. Mode REC/ PAUSE REC = PLAY Input Signal/Test Tape Input a 315Hz signal to the AUX � terminal of XC-L5. STD�632 test tape and record/ playback the 315Hz signal. Adjustment Points Measurement Points Adjustment Value Remarks
1
Input signal level L ch R ch
�7.7 dBV
TP L (W185) TP R (W183) ( MAIN UNIT) Repeat recording, playback and adjustment until playback level of the 315Hz signal becomes �7.7dBV±0.5dB.
VR2441 VR2442
2
*:
In case of adjustment as a single unit, enter the signal at 13P(RECL) and 15P(RECR) of CN2601(MAIN UNIT). At this time, connect an output buffer amplifier to the oscillator, and then connect a series resistor (180 �) after the impedance has become sufficiently low. (For MPX filter impedance matching)
24
|
|
|
> |
|