Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
In a word AWESOME.
I never expected the quality and abundant content that I got with this manual. Everything you'd ever want to know from a service perspective is found in this manual, along with... as a bonus, operating instructions on how to use the unit. WOW. Very impressed with the quality of the manual. You won't be disappointed if you're looking for the EVS900 service manual.
;
I thank Owen-Manuals.com for the wonderful service rendered to me, and this manual which I purchased helped me a lot in servicing my Denon System, which was lying in a dead state.
Thanks Owner-Manual.com
;
I purchased this manual to repair my Teac set and with the support of this manual I rectified the problem.
Thanks Owner-Manuals.com
;
Excellent service manual, i didn't believe i could find it for such old product, it is very explanatory, managed to fix the disk player!!!
;
Nice manual. Clear copy and very rare, to boot. Great price, too!
1
2
3
4
� Mode for checking the load on the Jog dial
A
In this mode, the load (light/heavy) on the Jog dial while it is rotated is subjectively measured.
JOG Check Mode : ON
CALL POWER SW
+
FWD+ REV
B
POWER ON
FL display
Rotation speed
Time (msec)
Measuring method
C
In this state, if you rotate the Jog dial rapidly either clockwise or counterclockwise, figures are displayed. For example, if "16.14 0135" is displayed, it means as follows: 16.14: Highest speed (given that the normal [1x] speed is when it takes 1.8 sec for the Jog dial to rotate one full turn.) 0135: Time (msec) required for the Jog dial to decrease its speed from 3x speed to 1.5x speed As to the time required for the Jog dial to decrease its speed, if the measurement is performed for several times repeatedly, from the second measurement and afterward, the average of the current required time and the previous required time is displayed. Thus, after several measurements, the result becomes closer to the mean. Notes � Perform the measurement of load on the Jog dial more than three times. � The measurement result is displayed only when the Jog dial is rotated 7 times normal speed "07.00" or more.
D
Management value
Jog management value: 150 ± 25 (msec)
Load adjustment method
Remove the screw fixing the adjust plate, then screw it into the hole corresponding to the value (-1, -2, -3, +1, or +2) for a load to be added: -1, -2, -3 : To decrease the load +1, +2 : To increase the load
E
To decrease the load
Adjust plate
-3
-2
+2
To increase the load
-1 0 +1
JOG Check Mode : CANCEL
F
POWER OFF
72
1 2
CDJ-1000MK2
3 4
|
|
|
> |
|