Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
BE-4140
6. ADJUSTMENT
Perform this adjustment more than 30 minutes after the power is turned on.
7 Equipment used
� � � � � � Spectrum analyzer Oscilloscope Digital voltmeter Video SG Variable resistance attenuator Audio analyzer
BE-4140
DPS Assy
+5V (D) 1 D.GND 6
� FM linear detector � C.W.Signal Generator
Digital Voltmeter
VR1
6.1 DC5V Adjustment
1. Connect the digital voltmeter to CN1004 pin 1 [+5V (D)] and pin 6 [GND (D)] of the DPS ASSY (Connection Diagram 1). +0.02 2. Adjust VR1 of the POWER unit, set to 5.00V - 0.01V
CN1004
POWER Unit
Connection Diagram 1
6.2 Adjustment of DPS ASSY (Video SCR ASSY)
� If deviation of the time axis occurs on the oscilloscope screen, or to move the screen to have a better view, perform fine adjustment using a delay. However do not change the ranges of the vertical and horizontal axes. � When reading the waveform on the oscilloscope screen, read the center of the waveform noise. � If the signal waveform on the oscilloscope is difficult to read, adjust the luminance.
DPS ASSY
VIDEO IN CN3001 (J1001)
VR1004 (RV1004) VIDEO OUT CN3002 (J1002) VR1003 (RV1003) IC1021 IC1020
6.2.1 Adjustment of video output pedestal potential
1. Connect the equipment as shown by the dotted lines in Connection Diagram 2. 2. Set the equipment as shown below. a. Oscilloscope 0.1V/div (DC mode) 5µs/div H-SYNC TRG. b. Video SG Staircase signal (1 Vp-p/75�) 3. Set the oscilloscope to the GND mode, and adjust the oscilloscope so that the luminance line is at the center of the oscilloscope. 4. Connect the equipment to the CN3002 (J1002) of the DPS ASSY using a tool as shown by the lines in Connection Diagram 2. 5. Set the unit to the STANDBY mode. The other functions can be set as desired. 6. Set the oscilloscope to the DC mode, and adjust VR1004 (RV1004) in the DPS ASSY so that the pedestal potential of the video waveform satisfies the GND potential set at step 3 (within 0±0.02V).
VIDEO SG
FL1002 IC1016
VR1001 (RV1001) CN1007
Fig.1 Adjustment Locations
BE-4140 Video in DPS ASSY CN3001 (VIDEO SCR ASSY) (J1001) VR1004 (RV1004)
Video out CN3002 (J1002)
OSILLOSCOPE
Staircase signal 1Vp-p/75�
Terminated at 75�
Connection Diagram 2
47
|
|
|
> |
|