Who's Online
There currently are 5884 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Thanks to this service manual I repaired my old camcorder! The manual perfectly explains how to disassemble the camcorder step by step.
;
This manual is very useful because it presents the technical specifications of the cd player, including the manufacturer of the reader, this helps if you need to replace it. It also displays the settings and layout of the circuit.
;
Manual was a good representation of service infomation for the EWV404. It worked well for my repair.
;
Great quality copy, right what I was looking for, all I need to fix my radio.
Thanks
;
I BOUGHT A PAIR OF INFINITY VINTAGE SPEAKERS THAT REQUIRED TO BE REPAIRED AND THE ELECTRONIC TECHNICIAN ASKED ME FOR THE SERVICE MANUAL.
I TRIED TO GET IT AT THE MANUFACTURER'S SITE WITH NO SUCCESS, SO I STARTED TO LOOK FOR IT IN THE WEB FOR A LONG TIME, UNTIL I FOUND THE SERVICE MANUAL IN THIS EXCELLENT SITE "OWNER'S MANUAL.COM".
NOW I HAVE MY SPEAKERS WORKING AND ENJOYING THE MUSIC I LIKE.
THANKS TO "OWNER`S MANUAL.COM" I RECOMMEND THIS SITE TO EVERYONE.
AVIC-505
6.2 CHECKING THE GRATING
- Checking the Grating After Changing the Service Pickup Unit
· Note : Unlike previous CD mechanism modules the grating angle of the Pickup unit cannot be adjusted after the Pickup unit is changed. The Pickup unit in the CD mechanism module is adjusted on the production line to match the CD mechanism module and is thus the best adjusted Pickup unit for the CD mechanism module. Changing the Pickup unit is thus best considered as a last resort. However, if the Pickup unit must be changed, the grating should be checked using the procedure below. · Purpose : To check that the grating is within an acceptable range. · Symptoms of Mal-adjustment : If the grating is off by a large amount symptoms such as being unable to close tracking, being unable to perform track search operations, or track searching taking a long time, may appear. · Method : · Measuring Equipment · Measuring Points · Disc · Mode
· Oscilloscope, Two L.P.F. · E, F, REFOUT · ABEX TCD-784 · TEST MODE
L.P.F. E REFOUT 100k� 390pF Xch Ych
Oscilloscope Oscilloscope
F REFOUT
100k� 390pF L.P.F.
CONTROL UNIT
· Checking Procedure 1. In test mode, load the disc and switch the 5V regulator on. 2. Using the � and � buttons, move the Pickup unit to the innermost track. 3. Press key � to close focus, the display should read "91". Press key MENU to implement the tracking balance adjustment the display should now read "8X". Press key � 4 times. The display will change, returning to "8X" on the fourth press. 4. As shown in the diagram above, monitor the LPF outputs using the oscilloscope and check that the phase difference is within 75° . Refer to the photographs supplied to determine the phase angle. 5. If the phase difference is determined to be greater than 75° try changing the Pickup unit to see if there is any improvement. If, after trying this a number of times, the grating angle does not become less than 75° then the mechanism should be judged to be at fault. · Note Because of eccentricity in the disc and a slight misalignment of the clamping center the grating waveform may be seen to "wobble" ( the phase difference changes as the disc rotates). The angle specified above indicates the average angle. · Hint Reloading the disc changes the clamp position and may decrease the "wobble".
64
|
|
|
> |
|